The Tiger Select is a revolutionary hand-held gas detector for the rapid, accurate detection of benzene and Total Aromatic Compounds (TACs).
| The instrument’s rugged body can withstand harsh environments | 
| When fully charged, the lithium-ion battery can last up the 24 hours | 
| Protection against a range of conditions and weather temperatures | 
| Fast Response Time & Clear Down | 
Specifications
| 
			 Resolution PPM model  | 
			
			 0.001 ppm (1 ppb) benzene in Tube mode 0.01 ppm in TAC mode 0.1 ppm in standard running mode:  | 
		
| 
			 Resolution PPB model  | 
			
			 0.001 ppm (1 ppb) benzene in Tube mode. 0.001 ppm in TAC modes. 0.001 ppm in standard running mode  | 
		
| 
			 Maximum Reading  | 
			
			 0 to 200 ppm benzene in tube mode, up to 20,000 ppm in TAC mode (gas dependent)  | 
		
| 
			 Response Time  | 
			
			 T90 < 2 seconds in normal running and TAC mode  | 
		
| 
			 Accuracy  | 
			
			 ± 10% display reading ± one digit benzene  | 
		
| 
			 Linearity  | 
			
			 ± 5% display reading ± one digit  | 
		
| 
			 Response Time  | 
			
			 120 seconds in Tube mode. Progressive indication of benzene breakthrough is displayed in real time  | 
		
| 
			 Intrinsically Safe Approvals  | 
			
			 II1GExiaIICT4Ga  | 
		
| 
			 Battery Life  | 
			
			 Li-ion: life up to 24 hours, charge time 6.5 hours  | 
		
| 
			 PID Lamps  | 
			
			 10.0eV Krypton PID lamp  | 
		
| 
			 Data Logging  | 
			
			 > 120,000 data log points including date and time stamp  | 
		
| 
			 Communication  | 
			
			 Direct USB 1.1  | 
		
| 
			 Calibration  | 
			
			 2 and 3 point calibration (via calibration kit accessory)  | 
		
| 
			 Alarm  | 
			
			 Flashing LED’s Amber (low alarm) Red (high alarm) Sounder 95 dBA at 300mm (12”) Vibration on alarm. Pre-programmed TWA and STEL*  | 
		
| 
			 Flow Rate  | 
			
			 >220 ml/min (150 cc/min flow alarm)  | 
		
| 
			 Temperature  | 
			
			 Operating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe)  | 
		
| 
			 Protection  | 
			
			 Designed to IP65 (heavy rain)  | 
		
| 
			 Weight & Dimensions  | 
			
			 Instrument (probe fitted,no tube attached) Length:465xHeight:89xDepth:61 mm (18.3×3.5×2.4”) Standardcase Packed weight: 5kg (176oz)  | 
		
*Model and gas dependent.
**Maximum reading is achieved with certain analytes such as ethanol.
***All specifications quoted are at calibration point and under the same ambient conditions.
Specifications are based on Benzene calibrations at 20 °C and 1000mBar
Tiger XT Select V1.0 This publication is not intended to form the basis of a contract and specifications can change without notice.
(Fence Electrode Technology, United States Patent, Patent No.: US 7.046,012 B2)